Emergency Physicians Tidewater 600 Gresham Dr STE 304, Norfolk, VA 23507 7574674200 (phone), 7574674173 (fax)
Emergency Physicians Tidewater 4092 Foxwood Dr STE 101, Virginia Beach, VA 23462 7574674200 (phone), 7574674173 (fax)
Education:
Medical School University of Louisville School of Medicine Graduated: 2009
Languages:
English Spanish
Description:
Dr. Mc Cann graduated from the University of Louisville School of Medicine in 2009. He works in Norfolk, VA and 1 other location and specializes in Emergency Medicine. Dr. Mc Cann is affiliated with Sentara Leigh Hospital, Sentara Norfolk General Hospital, Sentara Obici Hospital, Sentara Princess Anne Hospital and Sentara Virginia Beach General Hospital.
Scott Cann - Washougal WA, US Michael Huston - Vancouver WA, US Sergey N. Altukhov - Vancouver WA, US
Assignee:
SEH America, Inc. - Vancouver WA
International Classification:
B24B 1/00
US Classification:
451 44, 451 54, 451287
Abstract:
A slurry recycling apparatus having a first filter, a dirty side storage tank, slurry pump, second filter, clean side storage tank and slurry outlet, in which used slurry from an edge notch polishing apparatus is delivered to the first screen filter, transported to the dirty side slurry storage tank, pumped from the dirty side slurry storage tank through a second filter that filters out small particulate matter from the slurry and allows the slurry to pass to the clean side slurry storage tank, and finally to the edge notch polishing apparatus as needed. Slurry which is not immediately taken from the clean side slurry storage tank is continuously recycled through the second filter by overflowing from the clean side to the dirty side slurry storage tank where it is there pumped through the second filter back into the clean side slurry storage tank.
Wafer Image (Ads) Vision System To Automated Dimensioning Equipment (Ade) Communication Interface System
Curtis Paul Buchanan - Camas WA Thomas Read Paine - Vancouver WA Scott Alan Cann - Washougal WA
Assignee:
Seh America, Inc. - Vancouver WA
International Classification:
G06F 1900 G06G 764 G06G 766
US Classification:
36446828
Abstract:
In a semiconductor manufacturing process in which wafers are analyzed using a wafer image (ADS) vision system and automated dimensioning equipment (ADE), an automated communication interface system is provided. The interface system uses a programmable logic controller in combination with relays to communicate signals between the ADS vision system and the automated dimensioning equipment in response to signal indications in both. The programmable logic controller includes a plurality of timers for generating signals of selected duration as well as time delays of selected duration. The relays permit signals to be communicated in the face of signal system incompatibility between components. When a wafer in the automated dimensioning equipment is ready for optical analysis, the interface system responds by sending a start signal to the ADS vision system, which responds by analyzing the wafer and providing accept or reject indications. Signals representing the accept or reject indications are communicated to the automated dimensioning equipment, followed by an enter signal which is required by such equipment.