Search

Durk E Sijbolts

from Fremont, CA

Durk Sijbolts Phones & Addresses

  • 44619 Parkmeadow Dr, Fremont, CA 94539 • 5102495621
  • 47533 Westinghouse Dr, Fremont, CA 94539

Work

  • Position:
    Building and Grounds Cleaning and Maintenance Occupations

Education

  • Degree:
    High school graduate or higher

Us Patents

  • Low Profile Improved Radiopacity Intraluminal Medical Device

    view source
  • US Patent:
    20020193867, Dec 19, 2002
  • Filed:
    Apr 22, 2002
  • Appl. No.:
    10/127191
  • Inventors:
    Bennie Gladdish - Davie FL, US
    Marco Nino - Miami FL, US
    William Shaw - Miami FL, US
    Durk Sijbolts - Fremont CA, US
    Dennis Vaughan - Miami FL, US
  • International Classification:
    A61F002/06
  • US Classification:
    623/001150, 623/001340
  • Abstract:
    A stent or other intraluminal medical device having markers formed from housings integral with the stent and marker inserts having a higher radiopacity than the stent provides for more precise placement and post-procedural visualization in a vessel, by increasing the radiopacity of the stent under X-ray fluoroscopy. The housings are formed integral to the stent and the marker inserts are made from a material close in the galvanic series to the stent material and sized to substantially minimize the effect of galvanic corrosion. The housings are also shaped to minimize their impact on the overall profile of the stent.
  • Low Profile Improved Radiopacity Intraluminal Medical Device

    view source
  • US Patent:
    20120253455, Oct 4, 2012
  • Filed:
    Jun 12, 2012
  • Appl. No.:
    13/494416
  • Inventors:
    Marco Nino - Miami FL, US
    Durk C. Sijbolts - Fremont CA, US
    Dennis B. Vaughan - Miami FL, US
  • Assignee:
    Cordis Corporation - Bridgewater NJ
  • International Classification:
    A61F 2/86
  • US Classification:
    623 134
  • Abstract:
    A stent or other intraluminal medical device having markers formed from housings integral with the stent and marker inserts having a higher radiopacity than the stent provides for more precise placement and post-procedural visualization in a vessel, by increasing the radiopacity of the stent under X-ray fluoroscopy. The housings are formed integral to the stent and the marker inserts are made from a material close in the galvanic series to the stent material and sized to substantially minimize the effect of galvanic corrosion. The housings are also shaped to minimize their impact on the overall profile of the stent.

Get Report for Durk E Sijbolts from Fremont, CA
Control profile